Service · NEURA POD by NEURA INFRA
NEURA POD Modular AI Data Center Construction
A modular AI data-center solution by NEURA INFRA

Engineering
What NEURA POD is
The name for how we build modular AI data centers.
NEURA POD is the container-sized AI factory module by Neura Infra — a single factory-integrated unit, engineered following NVIDIA DSX guidelines, that ships by road and lands on a prepared site to be installed, commissioned and handed over. NEURA STACK extends the same modular approach as stackable building blocks that combine to scale capacity.
Project scope
Project delivery scope.
These stages frame the project discussion. Services, responsibilities and deliverables are confirmed in each project proposal.
01
Design coordination
02
Factory integration
03
Logistics & site integration
04
Installation
05
Commissioning
06
Operational handover
Engineering & construction
Built in a factory. Proven before it ships.
NEURA POD treats a data center the way heavy industry treats equipment: engineered once, manufactured under control, tested as a system and delivered to site with its evidence already recorded. The method below is how our delivery programme is structured on every project.
Items marked “concept targets” describe the NEURA POD conceptual design and are indicative only; final engineering is confirmed per project against the client’s design basis and applicable site conditions.
NEURA INFRA / AI factory infrastructure

Engineering
Modular infrastructure for AI factories.
Repeatable power, cooling and IT building blocks are central to Neura Infra’s modular approach. AI factory reference designs provide industry context for coordinating these systems at scale.
NEURA POD / engineered to NVIDIA DSX guidelines
From reference design to factory integration.
NEURA POD is Neura Infra’s container-sized AI factory module — factory-integrated to fit a standard shipping-container envelope so it ships by road and lands on a single pad — engineered following the guidelines of NVIDIA’s published DSX reference designs: standardized compute, power and cooling building blocks, preintegrated before delivery.
Official NVIDIA reference / DSX POD
Factory integration. Repeatable deployment.
NVIDIA describes DSX POD as a factory-integrated, containerized reference design built for the Vera Rubin platform. The principles below inform NEURA POD’s engineering approach; they are not confirmed NEURA equipment specifications.
NEURA POD / Concept design
800 VDC power. Liquid-cooled IT. One integrated pad.
A proposed factory-integrated compute module, engineered following NVIDIA DSX guidelines as published design inputs. The configuration below is conceptual, not a validated or certified NVIDIA implementation.

- Compute
- Vera Rubin NVL72-class racks
- Module
- 40 ft HC · factory-integrated
- IT load
- 100% liquid-cooled
- Support
- Dedicated support and network racks
Concept drawing set NI-DSX-DWG-003 · October 2026. Not for construction. Indicative specifications, subject to validation against NVIDIA’s released reference designs, the client’s design basis and local requirements.
Technical drawings under MNDANotes & trademarks +
NVIDIA’s DSX POD is a specific containerized reference design; NEURA POD follows that container-sized approach, while NEURA STACK applies the same modular thinking as stackable building blocks at broader site scale. NEURA POD is Neura Infra’s own brand and is not an NVIDIA product. Both are engineered to align with NVIDIA’s published reference architectures; no certification, endorsement or partnership is claimed or implied.
NVIDIA, DSX, Vera Rubin and other NVIDIA marks are trademarks or registered trademarks of NVIDIA Corporation in the United States and other countries.
Delivery programme
Parallel workstreams. Witnessed milestones.
Site works progress while modules are fabricated and tested. Permitting and utility connections are progressed before design freeze to reduce dependencies on the fabrication programme.
Indicative months from design freeze
Design freeze · procurement
At month 0
Site civils · foundations
Months 0–2
Module fabrication · FAT
Months 0–4
Shipping · assembly
Months 4–6
Testing · commissioning
Months 6–8
Handover · O&M
Months 8–10
Partner-reported delivery record
From8months
From design freeze to certified building, reported for the FPD partner’s first 20 MW phase of a 120 MW reference project.
This is a partner reference, not a Neura Infra delivery guarantee. Project timing depends on scope, approvals, utility readiness, logistics and site conditions. Handover and O&M mobilisation may continue beyond building certification.
Client-witnessed gates
01
Design freeze
Envelope, interfaces, scope, price and programme committed.
02
FAT
Factory acceptance testing before modules ship.
03
SAT
Site acceptance testing of integrated systems after assembly.
04
Go-live
Building certification, tenant acceptance and operational handover.
Start a project
Request a consultation.
Share your site, capacity and timeline requirements and our engineering team will respond.