NEURA POD Modular AI Data Center Construction

A modular AI data-center solution by NEURA INFRA

NEURA POD logo

Engineering

What NEURA POD is

The name for how we build modular AI data centers.

NEURA POD is the container-sized AI factory module by Neura Infra — a single factory-integrated unit, engineered following NVIDIA DSX guidelines, that ships by road and lands on a prepared site to be installed, commissioned and handed over. NEURA STACK extends the same modular approach as stackable building blocks that combine to scale capacity.

Project scope

Project delivery scope.

These stages frame the project discussion. Services, responsibilities and deliverables are confirmed in each project proposal.

01

Design coordination

02

Factory integration

03

Logistics & site integration

04

Installation

05

Commissioning

06

Operational handover

Engineering & construction

Built in a factory. Proven before it ships.

NEURA POD treats a data center the way heavy industry treats equipment: engineered once, manufactured under control, tested as a system and delivered to site with its evidence already recorded. The method below is how our delivery programme is structured on every project.

Items marked “concept targets” describe the NEURA POD conceptual design and are indicative only; final engineering is confirmed per project against the client’s design basis and applicable site conditions.

NEURA INFRA / AI factory infrastructure

NEURA POD — AI factories at scale

Engineering

Modular infrastructure for AI factories.

Repeatable power, cooling and IT building blocks are central to Neura Infra’s modular approach. AI factory reference designs provide industry context for coordinating these systems at scale.

NEURA POD / engineered to NVIDIA DSX guidelines

From reference design to factory integration.

NEURA POD is Neura Infra’s container-sized AI factory module — factory-integrated to fit a standard shipping-container envelope so it ships by road and lands on a single pad — engineered following the guidelines of NVIDIA’s published DSX reference designs: standardized compute, power and cooling building blocks, preintegrated before delivery.

Official NVIDIA reference / DSX POD

Factory integration. Repeatable deployment.

NVIDIA describes DSX POD as a factory-integrated, containerized reference design built for the Vera Rubin platform. The principles below inform NEURA POD’s engineering approach; they are not confirmed NEURA equipment specifications.

NEURA POD / Concept design

800 VDC power. Liquid-cooled IT. One integrated pad.

A proposed factory-integrated compute module, engineered following NVIDIA DSX guidelines as published design inputs. The configuration below is conceptual, not a validated or certified NVIDIA implementation.

Compute module · rack layout
Rack fronts serviced through double-door sets. A rear service zone accommodates TCS drops and the 800 VDC busway.
Compute
Vera Rubin NVL72-class racks
Module
40 ft HC · factory-integrated
IT load
100% liquid-cooled
Support
Dedicated support and network racks

Concept drawing set NI-DSX-DWG-003 · October 2026. Not for construction. Indicative specifications, subject to validation against NVIDIA’s released reference designs, the client’s design basis and local requirements.

Technical drawings under MNDA
Notes & trademarks +

NVIDIA’s DSX POD is a specific containerized reference design; NEURA POD follows that container-sized approach, while NEURA STACK applies the same modular thinking as stackable building blocks at broader site scale. NEURA POD is Neura Infra’s own brand and is not an NVIDIA product. Both are engineered to align with NVIDIA’s published reference architectures; no certification, endorsement or partnership is claimed or implied.

NVIDIA, DSX, Vera Rubin and other NVIDIA marks are trademarks or registered trademarks of NVIDIA Corporation in the United States and other countries.

Delivery programme

Parallel workstreams. Witnessed milestones.

Site works progress while modules are fabricated and tested. Permitting and utility connections are progressed before design freeze to reduce dependencies on the fabrication programme.

Indicative months from design freeze

  1. Design freeze · procurement

    At month 0

  2. Site civils · foundations

    Months 0–2

  3. Module fabrication · FAT

    Months 0–4

  4. Shipping · assembly

    Months 4–6

  5. Testing · commissioning

    Months 6–8

  6. Handover · O&M

    Months 8–10

Partner-reported delivery record

From8months

From design freeze to certified building, reported for the FPD partner’s first 20 MW phase of a 120 MW reference project.

This is a partner reference, not a Neura Infra delivery guarantee. Project timing depends on scope, approvals, utility readiness, logistics and site conditions. Handover and O&M mobilisation may continue beyond building certification.

Client-witnessed gates

01

Design freeze

Envelope, interfaces, scope, price and programme committed.

02

FAT

Factory acceptance testing before modules ship.

03

SAT

Site acceptance testing of integrated systems after assembly.

04

Go-live

Building certification, tenant acceptance and operational handover.

Start a project

Request a consultation.

Share your site, capacity and timeline requirements and our engineering team will respond.